Diagnostic Procedure 2
DIAGNOSTIC PROCEDURE 2 / With CONSULT-II Scan ToolInspecting SRS malfunctioning parts by using CONSULT-II - Diagnosis mode
1. Turn ignition switch OFF.
2. Connect CONSULT-II to the data link connector.
3. Turn ignition switch ON.
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [CURRENT]".
7. Diagnostic code is displayed on "SELF-DIAG [CURRENT]".
If no malfunction is detected on "SELF-DIAG [CURRENT]" even though malfunction is detected in "SRS Operation Check" ([1][2]Component Tests and General Diagnostics), refer to "DIAGNOSTIC PROCEDURE 4 (CONTINUED FROM DIAGNOSTIC PROCEDURE 2)"(Diagnostic Procedure 4), to diagnose the following cases:
* Self-diagnostic result "SELF-DIAG [PAST]" (previously stored in the memory) might not be erased after repair.
* The SRS system malfunctions intermittently.
8. Compare diagnostic codes to "CONSULT-II Diagnostic Code Chart".
CONSULT-II Display Items ("Self-Diag [Current]")