4. ABS Actuator and Electric Control Unit Power and Ground Systems
Inspection 4 ABS Actuator and Electric Unit (Control Unit) Power and Ground SystemsINSPECTION PROCEDURE
1. SELF-DIAGNOSIS RESULT CHECK
Is the above displayed in the self-diagnosis display items?
YES >> GO TO 2.
NO >> Inspection End
2. CONNECTOR INSPECTION
1. Disconnect the ABS actuator and electric unit (control unit) connector, check the terminal to see if it is deformed, disconnected, loose, etc., and if there is an error, repair or replace the terminal.
2. Securely reconnect the connector and conduct self-diagnosis.
OK or NG
OK >> The connector terminal contact is loose, damaged, open or shorted.
NG >>GO TO 3.
3. ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER AND GROUND CIRCUIT INSPECTION
Disconnect ABS actuator and electric unit connector. Check continuity and voltage between connector terminals and ground.
OK or NG
OK >> Check battery (terminal looseness, power drop, etc.) Error. If there is an error, make repairs.
NG >> Corresponding harness circuit error. Repair the circuit.