Operation CHARM: Car repair manuals for everyone.

Diagnostic Procedure 2

Trouble Diagnosis with CONSULT-II

DIAGNOSTIC PROCEDURE 2

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.

1. Turn ignition switch OFF.




2. Connect CONSULT-II and CONSULT-II CONVERTER to the data link connector.
3. Turn ignition switch ON.




4. Touch "START (NISSAN BASED VHCL)".




5. Touch "AIR BAG".
If "AIR BAG" is not indicated, go to GI-39, "CONSULT-II Data Link Connector (DLC) Circuit". CONSULT-II Checking System




6. Touch "SELF-DIAG [CURRENT]".




7. Diagnostic code is displayed on "SELF-DIAG [CURRENT]".




If no malfunction is detected on "SELF-DIAG [CURRENT]" even though malfunction is detected in "SRS Operation Check", check the battery voltage. If the battery voltage is less than 9 V, charge or replace the battery. "DIAGNOSTIC PROCEDURE 3". If the battery voltage is OK, go to SRS-30, "DIAGNOSTIC PROCEDURE 4 (CONTINUED FROM DIAGNOSTIC PROCEDURE 2)" Diagnostic Procedure 4 diagnose the following cases:
- Self-diagnostic result "SELF-DIAG [PAST]" (previously stored in the memory) might not be erased after repair.
- The SRS system malfunctions intermittently.

Part 1:




Part 2:




Part 3:




CONSULT-II Diagnostic Code Chart ("SELF-DIAG [CURRENT]�)

NOTE:
- Follow the procedures in numerical order when repairing malfunctioning parts. Confirm whether malfunction is eliminated using air bag warning lamp or CONSULT-II each time repair is finished. If malfunction is still observed, proceed to the next step. When malfunction is eliminated, further repair work is not required.