With Manufacturer's Scan Tool
CONSULT-IICONSULT-II INSPECTION PROCEDURE
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communications
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Insert NVIS (NATS) program card into CONSULT-II.
Program card : NATS (AEN02C-1)
4. Turn ignition switch ON.
5. Touch "START".
6. Select "NATS V.5.0".
7. Perform each diagnostic test mode according to each service procedure.
For further information, see the "CONSULT-II OPERATION MANUAL IVIS/NVIS".
CONSULT-II DIAGNOSTIC TEST MODE FUNCTION
NOTE:
- When any initialization is performed, all IDs previously registered will be erased and all NATS ignition keys must be registered again.
- The engine cannot be started with an unregistered key. In this case, the system will show "DIFFERENCE OF KEY" or "LOCK MODE" as a self-diagnostic result on the CONSULT-II screen.
- In rare case, "CHAIN OF ECM-IMMU" might be stored as a self-diagnostic result during key registration procedure, even if the system is not malfunctioning.
HOW TO READ SELF-DIAGNOSTIC RESULTS
NVIS (NATS) SELF-DIAGNOSTIC RESULTS ITEM CHART