Operation CHARM: Car repair manuals for everyone.

With 7 Inch Display





INSPECTION AND ADJUSTMENT


Temperature Setting Trimmer


DESCRIPTION
If the temperature felt by the customer is different than the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.

HOW TO SET
With CONSULT-III
Perform "TEMP SET CORRECT" of HVAC work support item.






NOTE:
- When -3.0 °C (-6 °F) is corrected on the temperature setting set as 25.0 °C (77 °F), the temperature controlled by A/C auto amp. is 25.0 °C (77 °F) - 3.0 °C (-6 °F) = 22.0 °C (72 °F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.