Operation CHARM: Car repair manuals for everyone.

Temperature Setting Trimmer





AUXILIARY MECHANISM


Temperature Setting Trimmer


DESCRIPTION
If the temperature felt by the customer is different than the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.

OPERATING PROCEDURES
1. Begin self-diagnosis STEP 5 mode. Diagnosis System (A/C Auto AMP.).
2. Press fan control switch (up: +) to enter the set temperature setting trimmer mode from STEP 5, and then display shows "0�C (0�F)".
3. The indication temperature will be changed by 1�C (1�F) in range of -3�C (-6�F) to +3�C (+6�F) by pressing the temperature control switch each time.











NOTE:
- When -3�C (-6�F) is corrected on the temperature setting set as 25�C (75�F), the temperature controlled by A/C auto amp. is 25�C (75�F) - 3�C (6�F) = 22.0�C (69�F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.