Component Inspection (2)
DAYTIME RUNNING LIGHT RELAY CIRCUIT
Component Inspection (Daytime Running Light Relay-2)
1.CHECK DAYTIME RUNNING LIGHT RELAY-2
1. Turn the ignition switch OFF.
2. Disconnect daytime running light relay-2.
3. Apply battery voltage to daytime running light relay-2 between terminals 1 and 2.
4. Check continuity daytime running light of relay-2.
Does continuity exist?
YES - Daytime running light relay-2 is normal.
NO - Replace Daytime running light relay-2.