Special Repair Requirement
INSPECTION AND ADJUSTMENT
TRANSAXLE ASSEMBLY REPLACEMENT : Special Repair Requirement
CAUTION:
Immediately after TCM is replaced or after control valve or transaxle assembly is replaced (after TCM initialization is complete), self-diagnosis result of "P1701" may be displayed. In this case, erase self-diagnosis result using CONSULT-III. After erasing self-diagnosis result, perform DTC P1701 reproduction procedure and check that malfunction is not detected. P1701.
1.PREPARATION BEFORE WORK
With CONSULT-III
1. Start the engine.
CAUTION:
Never drive the vehicle.
2. Select "Data monitor" in "TRANSMISSION".
3. Select "ATFTEMP COUNT".
Is "ATFTEMP COUNT" 47 [equivalent to 20�C (68�F)] or more?
YES - GO TO 2.
NO - 1. Warm up the transaxle assembly until "ATFTEMP COUNT" reaches "47" [equivalent to 20�C (68�F)] or more.
2. GO TO 2.
2.PERFORM TCM INITIALIZATION
With CONSULT-III
1. Turn ignition switch OFF.
2. Turn ignition switch ON.
CAUTION:
Never start the engine.
3. Select "Self Diagnostic Results" in "TRANSMISSION".
4. Shift selector lever to "R" position.
5. Depress slightly the accelerator pedal (Pedal angle: 2.0/8) while depressing the brake pedal.
6. Select "Erase" with step 5.
7. Release brake pedal and accelerator pedal.
8. Turn ignition switch OFF while keeping the selector lever in "R" position.
9. Wait approximately 10 seconds.
10. Turn ignition switch ON while keeping the selector lever in "R" position.
11. Select "Special function" in "TRANSMISSION".
12. Select "CALIB DATA".
13. Check that "CALIB DATA" value is as shown as in the following table.
Is "CALIB DATA" value it?
YES - GO TO 3.
NO - GO TO 1.
3.CHECK AFTER WORK
1. Shift selector lever to "P" position.
2. Check that "P" is displayed on shift position indicator on combination meter.
NOTE:
It indicates approximately 1 or 2 seconds after shifting the selector lever to "P" position.
Does shift position indicator display "P"?
YES - INSPECTION END
NO - Check the following.
- The harness between TCM and ROM ASSY in transaxle assembly is open or shorted.
- Terminals disconnected, loose, or bent from connector housing.
- Power supply and ground of TCM. ( P1701.)