Main Power Window and Door Lock/Unlock Switch Power Supply and Ground Circuit Inspection
POWER WINDOW SYSTEM
Main Power Window and Door Lock/Unlock Switch Power Supply and Ground Circuit Inspection
1.CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/unlock switch connector D5 terminal 10, D11 terminal 19 and ground.
OK or NG
OK - GO TO 2.
NG - GO TO 3.
2.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between main power window and door lock/unlock switch connector and ground.
OK or NG
OK - Power supply and ground circuit are OK.
NG - Repair or replace harness.
3.CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and main power window and door lock/unlock switch.
3. Check continuity between BCM connector (A) and main power window and door lock/unlock switch connector (B).
4. Check continuity between BCM connector (A) and ground.
OK or NG
OK - GO TO 4.
NG - Repair or replace harness.
4.CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector M20 terminal 68, 69 and ground.
OK or NG
OK - Check the condition of the harness and the connector.
NG - Replace BCM. Service and Repair.