"LOCK" Warning Lamp (With M/T) Check
INTELLIGENT KEY SYSTEM
"LOCK" Warning Lamp (With M/T) Check
1.CHECK WARNING LAMP OPERATION
With CONSULT-III
- Check "INDICATOR" in "ACTIVE TEST" mode with CONSULT-III.
- Select "KNOB ON".
"LOCK" warning lamp should illuminate.
Without CONSULT-III
1. Turn ignition switch OFF.
2. While monitoring the combination meter warning lamps, turn ignition switch ON. "LOCK" warning lamp should illuminate for 1 second to perform a bulb check.
OK or NG
OK - Inspection End.
NG - Check combination meter. Combination Meters System Description.