1.CHECK FUSES
Check for blown combination meter fuses.





Are any combination meter fuses blown?
YES - Eliminate cause of malfunction before installing new fuse.
NO - GO TO 2
2.POWER SUPPLY CIRCUIT CHECK
1. Disconnect combination meter connector.
2. Check voltage between combination meter harness connector M24 terminals 1, 2, 14 and ground.





Do test results match chart?
YES - GO TO 3
NO - Check harness for open between combination meter and fuse.
3.GROUND CIRCUIT CHECK





1. Turn ignition switch OFF.
2. Check continuity between combination meter harness connector terminals 3, 4, 23 and ground.





Do test results match chart?
YES - Inspection End.