INSPECTION AND ADJUSTMENT
Inlet Port Memory Function (FRE)
DESCRIPTION
- If the ignition switch is turned to the OFF position while the FRE indicator is set to ON (fresh air intake), "Perform the memory" or "Do not perform the memory" of FRE indicator ON (fresh air intake) condition can be selected.
- If "Perform the memory" was set, the FRE indicator will be ON (fresh air intake) when turning the ignition switch to the ON position again.
- If "Do not perform the memory" was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT
Perform the "FRE MEMORY SET" of HVAC work support item.
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V
or less, the setting of the FRE memory function may be cancelled.