Meter Buzzer Circuit
METER BUZZER CIRCUIT
Description
- The buzzer for warning chime system is installed in the combination meter.
- The combination meter sounds the alarm buzzer based on the signals transmitted from various units.
Component Function Check
1. CHECK OPERATION OF METER BUZZER
1.Select "BUZZER" of "BCM" on CONSULT.
2.Perform "LIGHT WARN ALM" of "Active Test".
Does meter buzzer beep?
YES- INSPECTION END
NO- GO TO 2.
2. CHECK COMBINATION METER INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "BUZZER" monitor value.
BUZZER
Under the condition of buzzer input : On
Except above : Off
Is the inspection result normal?
YES- Replace combination meter.
NO- Replace BCM. Removal And Installation.
Diagnosis Procedure
1. CHECK POWER SUPPLY OF COMBINATION METER
Check power supply of combination meter. Combination Meter.
Is the inspection result normal?
YES- INSPECTION END
NO- Repair power supply circuit of combination meter. Combination Meter.