VDC Off Indicator Lamp
VDC OFF INDICATOR LAMP
Component Function Check
1. CHECK VDC OFF INDICATOR LAMP FUNCTION
Check that VDC OFF indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES- Inspection End.
NO- Proceed to diagnosis procedure. .
Diagnosis Procedure
1. PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES- Testing and Inspection.
NO- GO TO 2.
2. CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Type A (type A) and Type B (type B).
Is the inspection result normal?
YES- Replace ABS actuator and electric unit (control unit). Removal And Installation.
NO- Replace combination meter. Type A (type A) or Type B (type B).