C1109
C1109 POWER AND GROUND SYSTEM
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1. CHECK SELF DIAGNOSTIC RESULT
With CONSULT.
1.Turn the ignition switch ON.
2.Perform self diagnostic result.
Is DTC C1109 detected?
YES- Proceed to diagnosis procedure. Refer to "Diagnosis Procedure" .
NO- Inspection End.
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" Electrical Diagrams.
1. CONNECTOR INSPECTION
1.Turn ignition switch OFF.
2.Disconnect ABS actuator and electric unit (control unit) connectors.
3.Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal?
YES- GO TO 2
NO- Repair or replace as necessary.
2. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY CIRCUIT
Check voltage between ABS actuator and electric unit (control unit) connector E54 terminal 28 and ground.
Is the inspection result normal?
YES- GO TO 3
NO- Repair or replace malfunctioning components.
3. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Check continuity between ABS actuator and electric unit (control unit) connector E33 terminals 13, 38 and ground.
Is the inspection result normal?
YES- Replace ABS actuator and electric unit (control unit). Refer to "Removal and Installation" Removal And Installation.
NO- Repair or replace malfunctioning components.