Remote Keyless Entry Receiver
REMOTE KEYLESS ENTRY RECEIVER
Description
Receives Intelligent Key operation and transmits to BCM.
Component Function Check
1. CHECK FUNCTION
1.Select "INTELLIGENT KEY" of "BCM" using CONSULT.
2.Select "RKE OPE COUN1" in "DATA MONITOR" mode.
3.Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES- Remote keyless entry receiver is OK.
NO- Refer to "Diagnosis Procedure" .
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" Intelligent Key System.
1. CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1.Turn ignition switch OFF.
2.Check signal between BCM harness connector and ground using oscilloscope.
Is the inspection result normal?
YES- Replace BCM. Refer to "Removal and Installation" Service and Repair.
NO- GO TO 3.
2. CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
1.Disconnect BCM and remote keyless entry receiver connectors.
2.Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
3.Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace harness.
3. CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
Check voltage between remote keyless entry receiver harness connector and ground.
Is the inspection result normal?
YES- GO TO 4.
NO-1- Check 5A fuse No. 9 [located in fuse block J/B].
NO-2- Repair or replace harness between BCM and 5A fuse No. 9.
4. CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
Check continuity between remote keyless entry receiver harness connector and ground.
Is the inspection result normal?
YES- Replace remote keyless entry receiver. Refer to "Removal and Installation" Service and Repair.