Operation CHARM: Car repair manuals for everyone.

Combination Meter




POWER SUPPLY AND GROUND CIRCUIT

COMBINATION METER : Diagnosis Procedure

Regarding Wiring Diagram information, refer to "Wiring Diagram" [1][2]Electrical Diagrams.

1. CHECK FUSES

Check that the following fuses are not blown.





Is the fuse blown?
YES- Replace the blown fuse after repairing the affected circuit.
NO- GO TO 2.

2. POWER SUPPLY CIRCUIT CHECK

1.Disconnect combination meter connector.
2.Check voltage between combination meter harness connector M24 terminals 5, 21, 22 and ground.





Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace harness or connectors.

3. GROUND CIRCUIT CHECK

1.Turn ignition switch OFF.
2.Check continuity between combination meter harness connector M24 terminals 1, 2 and ground.





Is the inspection result normal?
YES- Inspection End.
NO- Repair or replace harness or connectors.