Combination Meter
POWER SUPPLY AND GROUND CIRCUIT
COMBINATION METER : Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" [1][2]Electrical Diagrams.
1. CHECK FUSES
Check that the following fuses are not blown.
Is the fuse blown?
YES- Replace the blown fuse after repairing the affected circuit.
NO- GO TO 2.
2. POWER SUPPLY CIRCUIT CHECK
1.Disconnect combination meter connector.
2.Check voltage between combination meter harness connector M24 terminals 5, 21, 22 and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace harness or connectors.
3. GROUND CIRCUIT CHECK
1.Turn ignition switch OFF.
2.Check continuity between combination meter harness connector M24 terminals 1, 2 and ground.
Is the inspection result normal?
YES- Inspection End.
NO- Repair or replace harness or connectors.