MAIN LINE BETWEEN M&A AND A-BAG CIRCUIT (WITH MANUAL A/C)
Diagnosis Procedure
1. CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
1.Turn the ignition switch OFF.
2.Disconnect the battery cable from the negative terminal.
3.Disconnect the following harness connectors.
-Combination meter
- BCM
4.Check the continuity between the combination meter harness connector and the BCM harness connector.
Is the inspection result normal?
YES (Present error)-Check CAN system type decision again.
YES (Past error)-Error was detected in the main line between the combination meter and the air bag diagnosis sensor unit.
NO- Repair the main line between the combination meter and the air bag diagnosis sensor unit.