Trunk Lid Opener Cancel Switch
TRUNK LID OPENER CANCEL SWITCH
Description
Cancels trunk lid open operation.
Component Function Check
1. CHECK FUNCTION
With CONSULT
Check trunk lid opener cancel switch TR CANCEL SW in Data Monitor mode with CONSULT.
Is the inspection result normal?
YES- Trunk lid opener cancel switch is OK.
NO- Refer to "Diagnosis Procedure" .
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" [1][2]Electrical Diagrams.
1. CHECK TRUNK LID OPENER CANCEL SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES- GO TO 5
NO- GO TO 2
2. CHECK TRUNK LID OPENER CANCEL SWITCH CIRCUIT
1.Disconnect BCM connector.
2.Check continuity between BCM connector and trunk lid opener cancel switch connector.
3.Check continuity between BCM connector and ground.
Is the inspection result normal?
YES- GO TO 3
NO- Repair harness or connector.
3. CHECK TRUNK LID OPENER CANCEL SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch connector and ground.
Is the inspection result normal?
YES- GO TO 4
NO- Repair or replace harness.
4. CHECK TRUNK LID OPENER CANCEL SWITCH
Refer to "Component Inspection" .
Is the inspection result normal?
YES- GO TO 5
NO- Replace trunk lid opener cancel switch.
5. CHECK INTERMITTENT INCIDENT
Refer to "Intermittent Incident" Intermittent Incident.
- Inspection End.
Component Inspection
1. CHECK TRUNK LID OPENER CANCEL SWITCH
1.Disconnect trunk lid opener cancel switch connector.
2.Check continuity between trunk lid opener cancel switch terminals.
Is the inspection result normal?
YES- Inspection End.
NO- Replace trunk lid opener cancel switch.