Removal And Installation
BLOWER MOTOR
Removal and Installation
REMOVAL
1.Disconnect the negative battery terminal. Refer to "Removal and Installation" Removal and Replacement.
2.Remove the lower knee protector (LH). Refer to "Exploded View" Exploded View.
3.Remove the accelerator pedal assembly. Refer to "Removal and Installation" Removal And Installation.
4.Remove the brake pedal assembly. Refer to "Removal and Installation" Removal And Installation.
5.Disconnect the harness connectors from the blower motor.
6.Disconnect the harness connector from the thermo control amp.
7.Remove the blower motor screw (A).
8.Press the flange holding hook and turn blower motor counterclockwise.
9.Remove the blower motor.
INSTALLATION
Installation is in the reverse order of removal.