Blower Fan On Signal
BLOWER FAN ON SIGNAL
Component Function Check
1. CHECK BLOWER FAN ON SIGNAL
With CONSULT
1.Turn ignition switch ON.
2.Select "AIR CONDITIONER" of "BCM" using CONSULT.
3.Select "FAN ON SIG" in "DATA MONITOR" mode, and check status under the following condition.
Is the inspection result normal?
YES- Inspection End.
NO- Refer to "Diagnosis Procedure" .
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" Manual Air Conditioning System or "Wiring Diagram" Manual Heater System.
1. CHECK BLOWER FAN ON SIGNAL
1.Turn ignition switch OFF.
2.Disconnect front air control harness connector.
3.Turn ignition switch ON.
4.Check output waveform between front air control and ground with using oscilloscope.
Is the inspection result normal?
YES- Replace front air control. Refer to "Removal and Installation" Removal and Installation.
NO- GO TO 2.
2. CHECK BLOWER FAN ON SIGNAL CIRCUIT FOR OPEN
1.Turn ignition switch OFF.
2.Disconnect BCM connector.
3.Check continuity front air control harness connector and BCM harness connector.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair harness or connector.
3. CHECK BLOWER FAN ON SIGNAL CIRCUIT FOR SHORT
Check continuity between front air control harness connector and ground.
Is the inspection result normal?
YES- Replace BCM. Refer to "Removal and Installation" Service and Repair or "Removal and Installation" Service and Repair.
NO- Repair harness or connector.