Interior Room Lamp Control Circuit
INTERIOR ROOM LAMP CONTROL CIRCUIT
Description
Controls each interior room lamp (ground side) by PWM signal.
NOTE:
PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming).
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following are normal.
- Interior room lamp power supply
- Map lamp bulb
- Room lamp bulb
1. CHECK INTERIOR ROOM LAMP CONTROL FUNCTION
CONSULT
1.Switch the map lamp switch or interior room lamp switch to DOOR.
2.Turn ignition switch ON.
3.Select INT LAMP of BCM (INT LAMP) ACTIVE TEST item.
4.While operating the test items, check that each interior room lamp turns ON/OFF.
On: Interior room lamp gradual brightening
Off: Interior room lamp gradual dimming
Does the interior room lamp turns ON/OFF (gradual brightening/dimming)?
YES- Interior room lamp control circuit is normal.
NO- Refer to "Diagnosis Procedure" .
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" Interior Room Lamp Control System.
1. CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
CONSULT
1.Turn ignition switch OFF.
2.Remove all the bulbs of map lamp and interior room lamp.
3.Turn ignition switch ON.
4.Select INT LAMP of BCM (INT LAMP) ACTIVE TEST item.
5.While operating the test item, check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 2.
Fixed ON-GO TO 3.
Fixed OFF-Replace BCM after making sure battery saver output/power supply circuit is not shorted to voltage. Refer to "Removal and Installation" Service and Repair (with Intelligent Key) or "Removal and Installation" Service and Repair (without Intelligent Key).
2. CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect BCM connector and map lamp connector or interior room lamp connector.
3.Check continuity between BCM harness connector and map lamp harness connector or interior room lamp harness connector.
With map lamp
Is the inspection result normal?
YES- Check that map lamp or interior room lamp has no internal open circuit.
NO- Repair or replace harness or connector.
3. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect BCM connector.
3.Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- Replace BCM after making sure battery saver output/power supply circuit is not shorted to voltage. Refer to "Removal and Installation" Service and Repair (with Intelligent Key) or "Removal and Installation" Service and Repair (without Intelligent Key).
NO- GO TO 4.
4. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
1.Disconnect interior room lamp connector or map lamp connector.
2.Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- Check that map lamp or interior room lamp has no internal short circuit.
NO- Repair or replace harness or connector.