S Terminal Circuit
S TERMINAL CIRCUIT
Description
The output voltage of the generator is controlled by the IC regulator at terminal "S" detecting the input voltage from battery.
The "S" terminal circuit detects the battery voltage to adjust the generator output voltage with the IC voltage regulator.
Diagnosis Procedure
Regarding Wiring Diagram information. Refer to "Wiring Diagram" [1][2]Electrical Diagrams.
1. CHECK "S" TERMINAL CONNECTION
1.Turn ignition switch OFF.
2.Check if "S" terminal is clean and tight.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair "S" terminal connection. Confirm repair by performing complete Charging system test using EXP-800 NI or GR8-1200 NI (if available). Refer to the applicable Instruction Manual for proper testing procedures.
2. CHECK "S" TERMINAL CIRCUIT
Check voltage between generator harness connector and ground.
Is the inspection result normal?
YES- Refer to "Work Flow (With EXP-800 NI or GR8-1200 NI)" With EXP-800 NI Or GR8-1200 NI or "Work Flow (Without EXP-800 NI or GR8-1200 NI)" Without EXP-800 NI Or GR8-1200 NI.
NO- Check harness for open between generator and fuse.