Generator Replacement
Generator Replacement (LNJ) (3.4L)
Removal Procedure
1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Service and Repair).
2. Remove the drive belt. Refer to Drive Belt Replacement (Service and Repair).
3. Disconnect the engine wiring harness electrical connector (1) from the generator.
4. Reposition the engine wiring harness boot (4).
5. Remove the generator terminal nut (2).
6. Remove the engine wiring harness terminal lead (3) from the generator.
7. Remove the generator bolts (1).
8. Remove the generator (2).
Installation Procedure
1. Install the generator (2).
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the generator bolts (1) and tighten to 50 Nm (37 lb ft).
3. Install the engine wiring harness terminal lead (3) to the generator.
4. Install the generator terminal nut (2) and tighten to 20 Nm (15 lb ft).
5. Position the engine wiring harness boot (4).
6. Connect the engine wiring harness electrical connector (1) to the generator.
7. Install the drive belt. Refer to Drive Belt Replacement (Service and Repair).
8. Install the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Service and Repair).