Scan Tool Does Not Power Up
CIRCUIT DESCRIPTIONThe data link connector (DLC) provides operating power for the scan tool at terminal 16 (battery positive voltage) and at terminal 4 (ground). The DLC provides the class 2 serial data signal at terminal 2 and signal ground at terminal 5. The scan tool will power up with the ignition off. Many modules, however, will not communicate unless the ignition is on.
TEST DESCRIPTION
Steps 1-4:
The number(s) below refer to the step number(s) on the diagnostic table.
1. The CIG fuse supplies power to terminal 16 of the DLC.
4. The battery positive voltage and ground circuits of the DLC are functioning properly. The malfunction must be due to the scan tool.