Power Windows - Inoperative - All
POWER WINDOWS INOPERATIVE - ALLDIAGNOSTIC AIDS
Each door module has a separate battery positive voltage circuit that is used exclusively for power window motor operation, however, the circuits are all fed by the same PWR WDO circuit breaker located in the rear fuse block. These circuits are in harness connector C3 of each front door module, and harness connector C2 of each rear door module. If the circuit opens at a point where the separate branches are all joined, all power windows will be inoperative. A short to ground in the circuit will open the PWR WDO circuit breaker, which will also cause all power windows to be inoperative.
TEST DESCRIPTION
Steps 1 - 5:
Steps 6 - 14:
The numbers below refer to the step numbers on the diagnostic table.
2. Determines if this is the correct chart for the symptom.
6. This step determines if a door module is internally shorted to ground, or the door module battery supply circuit is shorted to ground.