Power Mirrors - Inoperative
Power Mirrors Inoperative
Power Mirrors Inoperative (1 Of 2):
Power Mirrors Inoperative (2 Of 2):
Diagnostic Aids
If the power mirror system fuse is open and a short to ground in the battery positive voltage circuit is not detected, the fault could be a short to ground in one of the power mirror control circuits. This would open the power mirror system fuse when the mirror switch is pressed.
If both power mirrors are inoperative on one or more axis, the most probable cause is a power mirror switch failure. However, the fault could be an open circuit on two or more of the power mirror control circuits
The power mirror assembly is equipped with a pigtail harness and is not serviceable. If an internal open or short is detected in the power mirror assembly, replace the power mirror assembly.