Instrument Panel Inflatable Restraint Module Replacement
Instrument Panel Inflatable Restraint Module Replacement
Removal Procedure
Warning: Refer to SIR Inflator Module Handling and Storage Warning SIR Inflator Module Handling and Storage Warning.
Warning: Refer to SIR Warning SIR Warning.
Warning
A deployed dual stage inflator module will look the same whether one or both stages were used. Always assume a deployed dual stage inflator module has an active stage 2. Improper handling or servicing can activate the inflator module and cause personal injury.
1. Disable the SIR system. Refer to SIR Disabling and Enabling Service and Repair.
2. Remove the I/P trim pad. Refer to Instrument Panel Trim Pad Replacement Instrument Panel Trim Pad Replacement.
3. Remove the wire harness connector from the inflatable restraint I/P module.
4. Remove the bolts from the inflatable restraint I/P module and discard the bolts.
5. Remove the inflatable restraint I/P module.
Installation Procedure
1. Install the inflatable restraint I/P module.
Caution: Refer to Fastener Caution Fastener Caution.
Note: Use new bolts on the restraint module.
2. Install new bolts to the inflatable restraint I/P module.
Tighten the bolts to 10 Nm (89 lb in).
3. Install the wire harness connector to the inflatable restraint I/P module.
4. Install the I/P trim pad. Refer to Instrument Panel Trim Pad Replacement Instrument Panel Trim Pad Replacement.
5. Enable the SIR system. Refer to SIR Disabling and Enabling Service and Repair.
6. Deploy the old module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Pretensioner Handling and Scrapping Procedures.