Test Point 7
Fault Code 3 _ 17
Left front sensor contact resistance to battery voltage.
- Check front sensor at plug connection with ohmmeter.
1. Ohmmeter at terminal 1 and terminal 2
Display: 10 Ohm
2. Ohmmeter at terminal 2 and terminal 3
Display: 0...0.5 Ohm
If measured values are within tolerance, renew the control unit; if out of tolerance, renew the front sensor.