Test Point 9
Input 2 To Ground During Activation
Note: The fault may appear if auxiliary systems (e.g. interior monitor) have been fitted.
- Check auxiliary system of input 2.
- Using Special Tool 9540, check wire from alarm control unit plug II, terminal 8, to auxiliary system for short to ground.
- Check auxiliary system wiring for short to ground.