Operation CHARM: Car repair manuals for everyone.

Test Point 5



Doors(s) Open During Activation

- Check LH and RH door contact switches for shorts to ground.

- Check wire from alarm control unit plug II terminal 21 to the door contacts for short to ground, using Special Tool 9540.

- Check wire from relay base gong relay of central relay terminal D for short to ground.