Test Point 23
TEST POINT 23
Terminal 30 Open Circuit/Short To Ground
DTC 12
Fault Effect: Fault is only entered in the fault memory.
Note:
The Tiptronic control module is continuously supplied with battery voltage via pin 26 (+30).
1. Test voltage at control module connector pin 26.
If no battery positive voltage is displayed, check fuses Bi and F6 and check wire from the battery to the control module.