Auxiliary Blower Motor: Service and Repair
Auxiliary Blower Motor Replacement
Removal Procedure
1. Remove the instrument panel assembly. Refer to Instrument Panel Assembly Replacement (Instrument Panel Assembly Replacement).
2. Disconnect the electrical connectors (4) from the blower motor-auxiliary (3).
3. Remove the air outlet duct from the blower motor-auxiliary.
4. Remove the screws (2, 5) from the blower motor-auxiliary.
5. Remove the blower motor-auxiliary (3).
Installation Procedure
1. Install the blower motor-auxiliary (3).
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the retaining screws (2, 5) to the blower motor-auxiliary and tighten to 10 Nm (88 in. lbs.).
3. Install the air outlet duct to the blower motor-auxiliary.
4. Connect the electrical connectors (4) to the blower motor-auxiliary (3).
5. Install the instrument panel assembly. Refer to Instrument Panel Assembly Replacement (Instrument Panel Assembly Replacement).