Air Cleaner Fresh Air Duct/Hose: Service and Repair
Air Cleaner Resonator Outlet Duct Replacement
Removal Procedure
1. Disconnect the positive crankcase ventilation (PCV) fresh air tube (2) from the air cleaner resonator outlet duct (1).
2. Loosen the clamps at the following:
* Mass air flow (MAF)/intake air temperature (IAT) sensor
* Throttle body
3. Remove the air cleaner outlet duct bolt.
4. Remove the air cleaner outlet duct.
Installation Procedure
1. Install the air cleaner outlet duct.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the air cleaner outlet duct bolt and tighten to10 Nm (89 in. lbs.).
3. Tighten the clamps at the following:
* MAF/IAT sensor
* Throttle body
Tighten the clamps to 7 Nm (62 in. lbs.).
4. Connect the PCV fresh air tube (2) to the air cleaner resonator outlet duct (1).