Operation CHARM: Car repair manuals for everyone.

P0A8E



DTC P0A8E

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview)provides an overview of each diagnostic category.



DTC Descriptor
DTC P0A8E
- 14 Volt Power Module System Voltage High




Circuit/System Description

The auxiliary power module (APM) 12-volt output voltage is used for a 12-volt line APM output voltage control and a 12-volt line voltage sensor rationality check.


Conditions for Running the DTC

The engine is running.


Conditions for Setting the DTC

12-volt output voltage is greater than 18 volts for 2 seconds.


Action Taken When the DTC Sets

APM PWM off.


Conditions for Clearing the DTC

In both the hardware and software faults, normal range for 160 ms.


Diagnostic Aids

* Battery cable open (load dump).
* Fuse/relay box electrical failures.



Reference Information
Schematic Reference

Hybrid Controls Schematics ()
Connector End View Reference

Component Connector End Views (Connector Views)
Electrical Information Reference

* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)

Scan Tool Reference

Control Module References (Programming and Relearning)for Scan Tool Information


Circuit/System Testing

Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.


1. Inspect for any open fuses.
2. Inspect all the 12-volt battery connections for proper torque as follows:

* At Battery
* At SGCM
* At Fuse block
Refer to Fastener Tightening Specifications ().

3. If all connections were within torque specifications, replace the SGCM.



Repair Instructions

Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.


Control Module References (Programming and Relearning)for SGCM replacement, setup, and programming