Operation CHARM: Car repair manuals for everyone.

P1423

CH: DTC P1423 - EVAPORATIVE EMISSION CONTROL SYSTEM VENT CONTROL HIGH INPUT

DTC DETECTING CONDITION:
- Two consecutive driving cycles with fault

CAUTION: After repair or replacement of faulty parts, conduct CLEAR MEMORY MODE and INSPECTION MODE. Refer to How to Clear Diagnostic Trouble Codes. Clearing Diagnostic Trouble Codes





WIRING DIAGRAM

10CH1: CHECK OUTPUT SIGNAL FROM ECM.
1. Turn ignition switch to OFF.




2. Connect test mode connector at the lower portion of instrument panel (on the driver's side), to the side of the center console box.
3. Turn ignition switch to ON.

Connector & Terminal (B134) No.10 (+) - Chassis Ground (-):




4. While operating drain valve, measure voltage between ECM and chassis ground.

NOTE: Drain valve operation can be executed using Subaru Select Monitor. For procedure, Refer to "COMPULSORY VALVE OPERATION CHECK MODE".

CHECK: Does voltage change between 0 and 10 V?

YES: Go to step 10CH2.

NO: Even if MIL light up, the circuit has returned to a normal condition at this time. In this case, repair poor contact in ECM connector.

10CH2: CHECK OUTPUT SIGNAL FROM ECM.
1. Turn ignition switch to ON.

Connector & Terminal (B134) No.10 (+) - Chassis Ground (-):




2. Measure voltage between ECM and chassis ground.

CHECK: Is the voltage more than 10 V?

YES: Go to step 10CH4.

NO: Go to step 10CH3.

10CH3: CHECK POOR CONTACT.
Check poor contact in ECM connector.

CHECK: Is there poor contact in ECM connector?

YES: Repair poor contact in ECM connector.

NO: Replace ECM.

10CH4: CHECK HARNESS BETWEEN DRAIN VALVE AND ECM CONNECTOR.
1. Turn ignition switch to OFF.
2. Disconnect connector from drain valve.
3. Turn ignition switch to ON.

Connector & Terminal (B134) No.10 (+) - Chassis Ground (-):




4. Measure voltage between ECM and chassis ground.

CHECK: Is the voltage more than 10 V?

YES: Repair battery short circuit in harness between ECM and drain valve connector. After repair, replace ECM.

NO: Go to step 10CH5.

10CH5: CHECK DRAIN VALVE.
1. Turn ignition switch to OFF.

Terminals No.1 - No.2:




2. Measure resistance between drain valve terminals.

CHECK: Is the resistance less than 1 ohm?

YES: Replace drain valve and ECM.

NO: Go to step 10CH6.

10CH6: CHECK POOR CONTACT.
Check poor contact in ECM connector.

CHECK: Is there poor contact in ECM connector?

YES: Repair poor contact in ECM connector.

NO: Replace ECM.