P2089
DTC P2089 OCV SOLENOID VALVE SIGNAL A CIRCUIT SHORT (BANK 1)1. OUTLINE OF DIAGNOSIS
Detect open or short circuit of oil flow control solenoid valve.
Judge as NG when the current is large even though the duty signal is small.
2. ENABLE CONDITIONS
3. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
4. DIAGNOSTIC METHOD
Abnormality Judgment
Judge as NG when the continuous time until completing the malfunction criteria becomes 2 seconds or more.
Normality Judgment
Judge as OK and clear the NG when the continuous time of completing the malfunction criteria becomes more than 2 seconds.
5. DTC CLEAR CONDITION
- When the OK idling cycle is completed 40 times in a row
- When "Clear Memory" is performed
6. MALFUNCTION INDICATOR LIGHT CLEAR CONDITIONS
- When the OK driving cycle is completed 3 times in a row
- When "Clear Memory" is performed
7. FAIL SAFE
Make the oil flow control solenoid valve driving duty a predetermined value (9.36%).
8. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)