Operation CHARM: Car repair manuals for everyone.

System Operation Check Mode

System Operation Check Mode

OPERATION

1. Prepare the Subaru Select Monitor kit.






2. Prepare PC with Subaru Select Monitor installed.
3. Connect the USB cable to SDI (Subaru Diagnosis Interface) and USB port on the personal computer (dedicated port for the Subaru Select Monitor).

NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.

4. Connect the diagnosis cable to SDI.
5. Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).






CAUTION: Do not connect any scan tools except Subaru Select Monitor or general scan tool.

6. Start the PC.
7. Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
8. On {{Main Menu}} display, select {Each System Check}.
9. On {{System Selection Menu}} display, select {Engine Control System}.
10. Click the [OK] button after the information of engine type has been displayed.
11. On {{Engine Diagnosis}} display, select {System Operation Check Mode}.
12. The following items are displayed on the display.






1. FUEL PUMP CONTROL (OFF DRIVE)

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Fuel Pump Control}.
2. On {{Fuel Pump Control}} display, select {OFF Drive}.
3. On {{Start the Engine}} display, start the engine and click the [OK] button.
4. On {{OFF Drive}} display, click the [Execution] button and execute the OFF drive.
5. Click the [Cancel] button to stop the OFF drive.
6. Click the [F12 Exit] button to end the OFF drive. The screen will return to the {{Fuel Pump Control}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

2. FUEL PUMP CONTROL (ON/OFF DRIVE)

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Fuel Pump Control}.
2. On {{Fuel Pump Control}} display, select {ON/ OFF Dr.}.
3. On {{Turn Ignition Switch ON with Engine OFF}} display, turn the ignition switch to ON and click the [OK] button.
4. On {{ON/OFF Dr.}} display, click the [Execution] button and execute the ON/OFF drive.
5. Click the [Cancel] button to stop the ON/OFF drive.
6. [Click the [F12 Exit] button to end the ON/OFF drive. The screen will return to the {{Fuel Pump Control}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

3. IDLING IGNITION TIMING FIXED

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Fixed Idle Ignition Timing}.
2. On {{Start the Engine}} display, start the engine and click the [OK] button.
3. On {{Fixed Idle Ignition Timing}} display, click the [Execution] button and execute the idling ignition timing fixed.
4. Click the [Cancel] button to stop the idling ignition timing fixed.
5. Click the [F12 Exit] button to end the idling ignition timing fixed. The screen will return to the {{System Operation Check Mode}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

4. IDLE SPEED CONTROL

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Idle Speed Control}.
2. On {{Start the Engine}} display, start the engine and click the [OK] button.






4. Click the [Cancel] button to stop the idle speed control.
5. Click the [F12 Exit] button to end the idle speed control. The screen will return to the {{System Operation Check Mode}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

5. INJECTOR CONTROL (INJECTION STOP MODE)

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Injector Control}.
2. On {{Injector Control}} display, select {Injection Stop Mode}.
3. On {{Injection Stop Mode}} display, select the fuel injector to be stopped.
4. On {{Start the Engine}} display, start the engine and click the [OK] button.
5. On {{Fuel Injector #}} display, click the [Execution] button and execute the injection stop mode.
6. Click the [Cancel] button to stop the injection stop mode.
7. Click the [F12 Exit] button to return to the {{Injection Stop Mode}} display screen.
8. On {{Injection Stop Mode}} display, click the [Return] button to end the {{Injection Stop Mode}}. The screen will return to the {{Injector Control}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

6. INJECTOR CONTROL (INJECTION QUANTITY CONTROL)

CAUTION: After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode

1. On {{System Operation Check Mode}} display, select {Injector Control}.
2. On {{Injector Control}} display, select {Injection Quantity Control}.
3. On {{Start the Engine}} display, start the engine and click the [OK] button.






5. Click the [Cancel] button to stop the injection quantity control.
6. Click the [F12 Exit] button to end the injection quantity control. The screen will return to the {{Injector Control}} screen.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".