Diagnostic Chart For Self-Diagnosis
DIAGNOSTIC CHART FOR SELF-DIAGNOSISOPERATION
- Without left/right independent air conditioning function
- With left/right independent air conditioning function
1. A/C CONTROL MODULE SELF-DIAGNOSIS
- Without left/right independent air conditioning function
- With left/right independent air conditioning function
2. SENSOR CHECK TABLE
- Without left/right independent air conditioning function
NOTE: When the sunload sensor check is performed indoors or in the shade, it could be diagnosed as having an open circuit. Always check the sunload sensor at a location exposed to direct sunlight.
- Past malfunction will illuminate if four malfunctions or more were detected previously.
- To cancel the past malfunction, perform either of the following procedure: Disconnect the negative battery terminal or press and hold the FRESH/RECIRC switch for 5 seconds or more while performing selfdiagnosis step 3 - 7.
- With left/right independent air conditioning function
NOTE:
- When the sunload sensor check is performed indoors or in the shade, it could be diagnosed as having an open circuit. Always check the sunload sensor at a location exposed to direct sunlight.
- If there are multiple defective sensors, display occurs two times.
- Past malfunction will illuminate if four malfunctions or more were detected previously.
- To cancel the past malfunction, perform either of the following procedure: Disconnect the negative battery terminal or press and hold the FRESH/RECIRC switch for 5 seconds or more while performing selfdiagnosis step 3 - 4.
3. OPERATING MODE TABLE
- Without left/right independent air conditioning function
- With left/right independent air conditioning function
4. DRIVE SIGNAL CHECK TABLE
- Without left/right independent air conditioning function
NOTE:
- Past malfunction will illuminate if four malfunctions or more were detected previously.
- To cancel the past malfunction, perform either of the following procedure: Disconnect the negative battery terminal or press and hold the FRESH/RECIRC switch for 5 seconds or more while performing selfdiagnosis step 3 - 7.
- With left/right independent air conditioning function
NOTE:
- If there are multiple defective sensors, display occurs two times.
- Past malfunction will illuminate if four malfunctions or more were detected previously.
- To cancel the past malfunction, perform either of the following procedure: Disconnect the negative battery terminal or press and hold the FRESH/RECIRC switch for 5 seconds or more while performing selfdiagnosis step 3 - 4.