B1817
DTC B1817 SHORT IN PASSENGER'S AIRBAG DUAL STAGE - 2ND STEP (TO GROUND)DTC DETECTING CONDITION:
- Airbag main harness circuit is shorted to ground.
- Airbag module harness (passenger's side) circuit is shorted to ground.
- Passenger's airbag module is faulty.
- Airbag control module is faulty.
CAUTION: Before performing diagnosis, refer to "CAUTION" in "General Description". Caution
WIRING DIAGRAM: