B1606
DTC B1606 REFRIGERANT FLOW SENSOR CIRCUIT SHORTDTC DETECTING CONDITION:
Refrigerant pressure sensor circuit is shorted.
TROUBLE SYMPTOM:
- Compressor does not operate. (Variable compressor)
- DTC "B1606" Short-circuit in refrigerant pressure sensor was detected.
- DTC "-42" Short-circuit in refrigerant pressure sensor was detected.
WIRING DIAGRAM: