Operation CHARM: Car repair manuals for everyone.

Subaru Select Monitor

Subaru Select Monitor

OPERATION

1. HOW TO USE THE SUBARU SELECT MONITOR
1. Prepare the Subaru Select Monitor kit.






2. Prepare PC with Subaru Select Monitor installed.
3. Connect the USB cable to SDI (Subaru Diagnosis Interface) and USB port on the personal computer (dedicated port for the Subaru Select Monitor).

NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.

4. Connect the diagnosis cable to SDI.
5. Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).

CAUTION: Do not connect any scan tools except Subaru Select Monitor or general scan tool.






6. Start the PC.
7. Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
8. Call up DTC and data, then record them.

NOTE: For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".

2. READ CURRENT DATA FOR ENGINE (NORMAL MODE)
1. On [Main Menu] display, select {Each System Check}.
2. On [System Selection Menu] display, select {Engine Control System}.
3. Click the [OK] button after the information of engine type has been displayed.
4. On [Engine Diagnosis display], select {Current Data Display & Save}.
5. On [Current Data Display & Save display], select {Normal sampling}.
6. Using the scroll key, scroll the display screen up or down until the desired data is shown.

NOTE:
- For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".
- A list of the support data is shown in the following table.












3. READ CURRENT DATA FOR ENGINE (OBD MODE)
1. On [Main Menu] display, select {Each System Check}.
2. On [System Selection Menu] display, select {Engine Control System}.
3. Click the [OK] button after the information of engine type has been displayed.
4. On [Engine Diagnosis] display, select {OBD System}.
5. On [OBD Menu] display, select {Current Data Display & Save}.
6. On [Current Data Display & Save] display, select {All data display}.
7. Using the scroll key, scroll the display screen up or down until the desired data is shown.

NOTE:
- For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".
- A list of the support data is shown in the following table.












4. READ FREEZE FRAME DATA FOR ENGINE (OBD MODE)
1. On [Main Menu] display, select {Each System Check}.
2. On [System Selection Menu] display, select {Engine Control System}.
3. Click the [OK] button after the information of engine type has been displayed.
4. On [Engine Diagnosis] display, select {OBD System}.
5. On [OBD Menu] display, select {Freeze Frame Data Display}.

NOTE:
- For detailed operation procedures, refer to "PC application help for Subaru Select Monitor".
- A list of the support data is shown in the following table.









5. V.I.N. REGISTRATION
1. On [Main Menu] display, select {Each System Check}.
2. On [System Selection Menu] display, select {Engine Control System}.
3. Click the [OK] button after the information of engine type has been displayed.
4. On [Engine Diagnosis] display, select {Entry VIN}.
5. Perform the procedures shown on the display screen.