Operation CHARM: Car repair manuals for everyone.

Component Inspection


INSPECT IAC VALVE OPERATION

IAC Valve Closed:





(a) Connect the positive (+) lead from the battery to terminal +B and negative (-) lead to terminal RSC, and check that the valve is closed.

IAC Valve Open:





(b) Connect the positive (+) lead from the battery to terminal +B and negative (-) lead to terminal RSO, and check that the valve is open.
If operation is not as specified, replace the IAC valve.