DTC P043E EVAPORATIVE EMISSION SYSTEM REFERENCE ORIFICE CLOG UPContents
DTC Summary
Circuit Description
While the engine is running, if a predetermined condition (closed loop, etc.) is met, the purge VSV is opened by the ECM and stored fuel vapors in the canister are purged to the intake manifold. The ECM will change the duty cycle ratio of the purge VSV to control purge flow volume.
Purge flow volume is also determined by the intake manifold pressure. Atmospheric pressure is allowed into the canister through the vent valve to ensure that purge flow is maintained when negative pressure (vacuum) is applied to the canister.
Two monitors are run to confirm proper EVAP system operation.
Key-off monitor
This monitor checks for EVAP system leaks and pump module malfunctions. The monitor starts 5 hours ((+) 15 minutes) after the ignition switch is turned OFF. The 5 hours are required to allow enough time for the fuel to cool down. As a result, Fuel Tank Pressure (FTP) becomes stable and EVAP system monitor will be more accurate. Then, the electric vacuum pump creates negative pressure (vacuum) in the EVAP system and the pressure is measured. Finally, the ECM monitors for EVAP system leaks and pump module malfunctions based on EVAP pressure.
Purge flow monitor
If EVAP system pressure change is less than 7.5 mmHg (1 kPa) when the engine is running and the purge VSV is turned ON (closed), the ECM determines that the purge flow is insufficient.
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8:
Step 9:
Step 10:
Step 11 - 12:
Step 13 - 14:
Step 15 - 16:
Step 17 - 18:
Step 19:
Step 20:
Step 21 - 22:
Step 23:
Step 24 - 27:
Step 28 - 29:
Step 30 - 35:
Step 36:
Inspection Procedure
NOTE: When a vehicle is brought into the workshop, leave it as is. Do not change the vehicle condition. For example, do not tighten the fuel cap. Do not disassemble the pump module.
HINT: Using the hand held tester's monitor result allows you to confirm the EVAP system condition.
Monitor Description
When 5 hours have elapsed after the ignition switch is turned OFF, the electric vacuum pump creates negative pressure (vacuum) in EVAP system. Then ECM monitors for leaks and actuator malfunctions based on EVAP pressure.
a. P043E: 0.02 inch orifice clog
For order C, the vent valve is turned OFF (vent) and the vacuum pump creates negative pressure (vacuum) through 0.02 inch orifice. Then the pressure is measured. If pressure is lower than -33.75 mmHg (-4.5 kPa) the ECM determines that 0.02 inch orifice has a clog malfunction. The ECM stops the EVAP system monitor, illuminates the MIL and sets a DTC (2-trip detection logic).
b. P043F: 0.02 inch orifice high-flow
For order C, the vent valve is turned OFF (vent) and the vacuum pump creates negative pressure (vacuum) through 0.02 inch orifice. Then the pressure is measured. If pressure is higher than -7.5 mmHg (-1 kPa), the ECM determines that 0.02 inch orifice has a high-flow malfunction. The ECM stops the EVAP system monitor, illuminates the MIL and sets a DTC (2-trip detection logic).
OBDII Monitor Specification:
OBDII Monitor Specification