P050B
DTC P050B Cold Start Ignition Timing PerformanceDESCRIPTION
DTC Detection Condition:
This monitor will run when the engine is started at an engine coolant temperature of -10 to 50 °C (14 to 122 °F). The DTC will set after the engine idles for 13 seconds (2 trip detection logic).
The DTC is designed to monitor the ignition timing at cold start. When the engine is started at an engine coolant temperature of lower than 50 °C (122 °F), the ECM checks the ignition timing at engine idling. If the ignition timing advances beyond the specified level within 10 seconds, the ECM interprets this as a malfunction.
The MIL is illuminated and a DTC is set when the malfunction is detected in consecutive driving cycles (2 tip detection logic).
NOTE: When the negative battery terminal is disconnected during inspections or repairs, the ISC (Idle Speed Control) learning values are cleared. This DTC cannot be set with the ISC learning values cleared.
HINT: The ISC learning is performed when the engine is warmed up and has been idling for 5 minutes.
Monitor Strategy:
Typical Enabling Conditions:
Typical Malfunction Thresholds:
MONITOR DESCRIPTION
Step 1:
Step 1(Continued)-3:
Step 3(Continued)-7:
Step 7(Continued)-14:
Step 15:
INSPECTION PROCEDURE
HINT:
- DTC P050B may be set when the engine has the symptoms listed below. If necessary, check the trouble areas listed below.
- Read freeze frame data using the intelligent tester or Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction