Programming and Relearning
BRAKE CONTROL: VEHICLE STABILITY CONTROL SYSTEM: CALIBRATION
CALIBRATION
1. CLEAR ZERO POINT CALIBRATION (WHEN USING TECHSTREAM):
(a) Connect Techstream to the DLC3.
(b) Turn the ignition switch to the ON position.
(c) Operate Techstream to erase the codes (select "Reset Memory").
HINT: Refer to the Techstream operator's manual for further details.
(d) Using Techstream, perform zero point calibration of the yaw rate and deceleration sensor.
2. PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (WHEN USING TECHSTREAM):
NOTICE:
- While obtaining the zero point, do not vibrate the vehicle by tilting, moving or shaking it and keep it in a stationary condition. (Do not turn the ignition switch to the ON position.)
- Be sure to do this on a level surface (with an inclination of less than 1 %).
(a) Procedures for test mode.
(1) Check that the steering wheel is in the straight-ahead position and move the shift lever to the P position and apply the parking brake.
(2) Connect Techstream to the DLC3.
(3) Turn the ignition switch to the ON position.
(4) Set Techstream to test mode (select "Test Mode").
HINT: Refer to the Techstream operator's manual for further details.
(b) Obtain the zero point of the yaw rate and deceleration sensor.
(1) Keep the vehicle in the stationary condition on a level surface for 2 seconds or more.
(2) Check that the ABS warning light and VSC warning light blink.
- If the ABS warning light and VSC warning light do not blink perform zero point calibration again.
- The zero point calibration is performed only once after the system enters the test mode.
- Calibration cannot be performed again until the stored data is cleared once.
(c) Turn the ignition switch off and disconnect Techstream.
3. PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (WHEN USING SST CHECK WIRE):
NOTICE:
- While obtaining the zero point, do not vibrate the vehicle by tilting, moving or shaking it and keep it in a stationary condition. (Do not turn the ignition switch to the ON position.)
- Be sure to do this on a level surface (with an inclination of less than 1 %).
(a) Clear the zero point calibration.
(1) Turn the ignition switch to the ON position.
(2) Using SST, connect and disconnect terminals TS and CG of the DLC3 4 times or more within 8 seconds.
SST: 09843-18040
(b) Procedures for test mode.
(1) Turn the ignition switch off.
(2) Using SST, connect terminals TS and CG of the DLC3.
SST: 09843-18040
(3) Check that the steering wheel is in the straight ahead position and move the shift lever to the P position.
(c) Obtain the zero point of the yaw rate and deceleration sensor.
(1) Turn the ignition switch to the ON position.
(2) Keep the vehicle in a stationary condition on a level surface for 2 seconds or more.
(3) Check that the ABS warning light and VSC light blink (test mode).
- If the ABS warning light and VSC warning light do not blink perform zero point calibration again.
- The zero point calibration is performed only once after the system enters the test mode.
- Calibration cannot be performed again until the stored data is cleared once.
(d) Turn the ignition switch off and disconnect the SST from the DLC3.