P2759
A750F AUTOMATIC TRANSMISSION SYSTEM: P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DTC P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
The current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
HINT: *: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B). Duty Ratio (%) = A / (A + B) x 100
MONITOR DESCRIPTION
When an open or short is detected in the shift solenoid valve (SLU) circuit, the ECM determines that there is a malfunction. The ECM turns on the MIL and stores this DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
All
Case 1
Case 2
TYPICAL MALFUNCTION THRESHOLDS
Case 1
Case 2
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT TRANSMISSION WIRE (SLU)
(a) Disconnect the transmission wire connector from the transmission.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Connect the transmission wire connector to the transmission.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(d) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short):
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM
3. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove the shift solenoid valve SLU.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
NG -- REPLACE SHIFT SOLENOID VALVE SLU
OK -- REPAIR OR REPLACE TRANSMISSION WIRE