P2759
A750F AUTOMATIC TRANSMISSION SYSTEM: P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DTC P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.
HINT: *: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B). Duty Ratio (%) = A / (A + B) x 100
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
All
All of the following conditions are met: Condition (A) and (B)
Condition (A)
Condition (B)
TYPICAL MALFUNCTION THRESHOLDS
When either condition below is met: Condition (A) or (B)
Condition (A)
Condition (B)
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
(a) Disconnect the D63 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Disconnect the D74 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM
3. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove shift solenoid valve SLU.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
NG -- REPLACE SHIFT SOLENOID VALVE SLU
OK -- REPAIR OR REPLACE TRANSMISSION WIRE