Operation CHARM: Car repair manuals for everyone.

P2759








AB60F AUTOMATIC TRANSMISSION SYSTEM: P2759: Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

DTC P2759 - Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

DESCRIPTION

The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.





*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100





Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.
Standard:









MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS

All





All of the following conditions are met: Condition (A) and (B)

Condition (A)





Condition (B)





TYPICAL MALFUNCTION THRESHOLDS

When either condition below is met: Condition (A) or (B)

Condition (A)





Condition (B)





COMPONENT OPERATING RANGE





WIRING DIAGRAM





INSPECTION PROCEDURE

PROCEDURE

1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)





(a) Disconnect the D63 No. 1 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:





NG -- INSPECT SHIFT SOLENOID VALVE SLU
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)





(a) Disconnect the D74 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM
3. INSPECT SHIFT SOLENOID VALVE SLU
(a) Remove shift solenoid valve SLU.





(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:





(c) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
NG -- REPLACE SHIFT SOLENOID VALVE SLU
OK -- REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE