Operation CHARM: Car repair manuals for everyone.

Hydraulic Test








A750E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM (for 1GR-FE): HYDRAULIC TEST

HYDRAULIC TEST

1. PERFORM HYDRAULIC TEST





(a) Measure the line pressure.

NOTICE
- Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F).
- The line pressure test should always be carried out in pairs. One technician should observe the conditions of the wheels or wheel stoppers from outside the vehicle while the other is performing the test.
- Be careful to prevent SST hose from interfering with the exhaust pipe.
- This check must be conducted after checking and adjusting the engine.
- Perform with the A/C OFF.
- When conducting the stall test, do not continue for more than 5 seconds.

(1) Warm up the ATF (Automatic Transmission Fluid).
(2) Turn the ignition switch OFF.
(3) Lift the vehicle up.
(4) Remove the test plug on the transmission case center right side and connect SST.
SST: 09992-00095
09992-00231
09992-00271
(5) Lower the vehicle.
(6) Fully apply the parking brake and chock the 4 wheels.
(7) Start the engine and check the idling speed.
(8) Keep your left foot pressed firmly on the brake pedal and shift into the D position.
(9) Measure the line pressure when the engine is idling.
(10) Fully depress the accelerator pedal with your right foot. Quickly read the highest line pressure when the engine speed reaches stall speed.
(11) In the same manner, do the test in the R position.